Description

Model: TFA12TISTD

Product Lines: Industrial Tools

  • The RIVERLAKE integral hydraulic flange alignment tool assists in aligning / de-ovalizing large flanges and specifically can help resolve bolt-hole misalignment within the tower sections of wind turbines.
  • Set includes: 1 x TFA12TI Tool
    1 x Instruction Manual
    1 x Hard Case

Think Safety

Manufacturer’s rating of load and stroke are maximum safe limits. Good practice encourages using only 80% of these ratings!

Specifications

Maximum Reaction Force (metric ton)24
Min. Bolt Size(mm)45
Reaction Force 1 Min (metric ton)10
Reaction Force 1 Max (metric ton)12
Reaction Force 2 Min (metric ton)22
Reaction Force 2 Max (metric ton)24
Bolt Hole Diameter Min (mm) B45
Misalignment Min (mm) M0
Misalignment Max (mm) M65
Rise Min (mm) R150
Rise Max (mm) R250
Pipe Leg Drop Min (mm) D83
Pipe Leg Drop Max (mm) D123
Wing Reach Min (mm) W160
Wing Reach Max (mm) W203
Reaction Spacing (mm) H200
Height (mm)470
Width (mm)104
Length (mm)635
Weight (kg)31
dimensions 3

Series Comparison

ModelMax Reacttion Force(Ton)Min. Bolt Size(mm)Reacttion Force 1 Min(Ton)Reacttion Force 1 Max(Ton)Reacttion Force 2 Min(Ton)Reacttion Force 2 Max(Ton)Bolt Hole Dia Min(mm) BMisalignment Min(mm) MMisalignment Max(mm) MRise Min(mm) RRise Max(mm) RPile Leg Drop Min(mm) DPile Leg Drop Max(mm) DWing Reach Min(mm) WWing Reach Max(mm) WReaction Spacing(mm) HHeight(mm)Width(mm)Length(mm)Weight (kg)
TFA4TMSTD4250.41342505405425106451782452745134418
TFA12TEMIN244510122224450651442439013216020020047010451328.4
TFA15TEMIN27459122427450651442439013212016020043010451328
TFA12TISTD244510122224450651502508312316020320047010463531